BLTC-I - Ballast Load Transfer Control

The Ballast Load Transfer Control provides safe and effective emergency lighting from building emergency lighting systems with an alternate power source such as an emergency generator or inverter system. The BLTC operates automatically using an unswitched circuit to continuously monitor utility power, transferring to emergency power when normal power is lost. The units are designed and manufactured to comply with UL 924 regulations to transfer lighting loads form normal to emergency power.

     Cutsheet
     Specifications
     Specifier's Sheet
     JPEG Image Figures
     CAD Figures

Please Contact Us for Application.



BLTC-R - Ballast Load Transfer Control

The Ballast Load Transfer Control provides safe and effective emergency lighting from building emergency lighting systems with an alternate power source such as an emergency generator or inverter system. The BLTC operates automatically using an unswitched circuit to continuously monitor utility power, transferring to emergency power when normal power is lost. The units are designed and manufactured to comply with UL 924 regulations to transfer lighting loads form normal to emergency power.

     Cutsheet
     Specifications
     Specifier's Sheet
     JPEG Image Figures
     CAD Figures

Please Contact Us for Application.



BLTC 2.4 - Ballast Load Transfer Control 2.4

The BLTC 2.4 is designed to automatically override switches, dimmers, photocells, and other devices used to switch lighting loads.  Nine 24 incorporated all pertinent code requirements from NEC, NFPA, and UL along with requests from local code enforcement officials through out the country to provide a universally accepted product.  The design of the BLTC 2.4 integrates the answers to many of the questions posed to the engineering community about previous devices and simplifies installation for the electrical contractor.

     Cutsheet
     Installation Instructions
     JPEG Image Figures
     CAD Figures

Please Contact Us for Application.


FAI - Fire Alarm Interface

The Fire Alarm / Security Interface option allows BLTC units to be actuated by the building fire alarm system or security system in the event of an emergency condition (fire, storm, security breech, etc.) The FAI option will also cause the emergency fixtures controlled by the BLTC to illuminate during fire alarm testing. The BLTC will energize the emergency lighting fixtures controlled during a loss of normal power no matter what the state of the fire alarm system or interface.

Why This Feature
Building system, weather, or security related problems can cause the fire/security alarm to sound without a power failure. Firefighters have found higher lighting levels in smoke filled rooms reduce the occupant¹s disorientation allowing them to exit the building quickly during an emergency. With the FAI, there will always be the highest emergency lighting levels possible when the alarm sounds. The Fire alarm and/or security panel must supply a 24 volt contact closure to the BLTC to enable this option.

Please Contact Us for Application.



ESP - Emergency Sports Pack

Emergency Sports Pack is designed to provide automatic lighting when utility power is interrupted. The unit utilizes 35 watt metal halide lamp and ballast technologies combined with a unit inverter to provide 90 minutes of lighting. The unit provides a broad lighting distribution to cover bleachers at sporting events allowing spectators to leave safely. An integral strip heater is incorporated in the wet location listed inverter to keep it operational in all weather conditions. An integral test switch and LED indicator are incorporated in all units for testing.

     Cutsheet

Please Contact Us for Application.



ILUME - Imagilume

The Imagilume is a recessed grid or flanged LED luminaire used for ambient illumination in MRI facilities. The fixture provides ambient lighting while illuminating silk screened art of the owner’s choosing.

Features

  • Recessed 2x2 or 2x4 with 2-1/2” deep heavy gauge aluminum .7% ferrous housing
  • 12 volt 100,000 hour LED lamping
  • 120 or 277 volt alternating current to 12 volt direct current power supply
  • .125” thick Acrylic diffuser
  • (Optional) Emergency power supply with wall mounted heavy gauge steel housing, filtered battery charger/rectifier, maintenance free lead acid batteries, filtered DC output, temperature compensation, solid state charger, alarm system, output circuit breaker, 1008 or 924 emergency transfer switch or bypass relay. Emergency system to maintain 100% output for ninety (90) minutes.
     Cutsheet

Please Contact Us for Application.



BLTC_2.4_ENC_3 - BLTC 2.4 Triple Enclosure Accessory

  • Fabricated from 16 Gauge Carbon Steel
  • (3) Cut-outs in Door with Lexan Windows
  • Hinged
  • Coin Latch
  • Subpanel Studs
  • Wall mount holes
     Drawing w/Measurements

Please Contact Us for Application.



BLTC_2.4_ENC_1 - BLTC 2.4 Single Enclosure Accessory

 

Please Contact Us for Application.


TD_HID - Time Delay for HID Applications

Time Delay for HID Applications for all BLTC products